MODEL NUMBER | MANUFACTURER | CONNECTION | COOLING CAPACITY R134A (Kw) (1) | COOLING CAPACITY R407C (Kw) | POWER SUPPLY (V/Hz/Ph) | SHIPPING WEIGHT(KG) | OIL QUANTITY (L) (2) | SUCTION DIAMETER | DISCHARGE DIAMETER | CRANKCASE HEATER | ORDERING NUMBER | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
CSHA 10 T | Trane | Brazed | 20.7 | 30.7 | 400/50/3 | 78 | 3.8 | 1"3/8 | 7/8" | HTR0116E | COM07257 | |
CSHA 15 T | Trane | Brazed | 30.4 | 49.5 | 400/50/3 | 100 | 6.6 | 1"5/8 | 1"1/8 | HTR0117E | COM07558 | |
CSHA 10 T | Trane | Brazed | 20.7 | 33.7 | 400/50/3 | 80.0 | 3.8 | 1"3/8 | 7/8" | HTR0116E | COM0756E | |
CSHA 15 T | Trane | Brazed | 30.4 | 43.4 | 400/50/3 | 103.0 | 6.6 | 1"5/8 | 1"1/8 | HTR0117E | COM0757E |
1 - Duties given at 54.4°C condensing temp., 7.2°C evaporating temp., 8.3°C subcooling, 11.1°C superheat. (ARI conditions) and 50 Hz. For 60 Hz, multiply capacity by 1.2.
2 - Compressors are supplied with oil (Oil: see oil tables).